Product category:
Heatsinks and Thermal Management
News Release from: Emerson Network Power Adaptive Power and Cooling | Subject: Liebert XDFN
Edited by the Electronicstalk Editorial
Team on 26 December 2006
Cool answer for high-density server
racks
The Liebert XDFN self-contained cooling module capacity is regulated by the use of digital control technology, an innovative solution exclusively offered by Liebert.
To deal with the problem of increasing heat generation in high-density server racks, Emerson Network Power has developed the Liebert XDFN, an all-in-one cabinet solution for systems producing up to 25kW per rack, which offers the great advantage of dissipating heat directly in the rack and safeguarding the continuous operation of equipment, without requiring restructuring within the data-centre area With built in precision cooling, power protection and distribution, offering full redundancy and backup ventilation, server location rack, monitoring and fire extinguishing system, Liebert XDFN cools the servers not the room, each cabinet working independently
This article was originally published on Electronicstalk on 12 Feb 2007 at 8.00am (UK)
Related stories
Cooling architecture addresses whole systems
The Liebert Adaptive Architecture is a set of solutions and services that include precision cooling, power protection and monitoring.
Uninterruptible supplies communicate with Cisco
UPS technology notifies system routers about minimum battery levels using a dedicated communication port that is completely isolated from the UPS circuit.
Liebert XDFN features an innovative 32bit microprocessor control enabling integration in an SNMP monitoring system or browsing via the web.
In addition, the cooling module is equipped with humidity control.
Also featured is a fire extinguishing system, based on Vesda laser focus technology, that continuously monitors the air inside both the rack and cooling module, introducing an inert gas to reduce the oxygen level if smoke is detected.
The Liebert XDFN self-contained cooling module capacity is regulated by the use of digital control technology, an innovative solution exclusively offered by Liebert.
The cooling module is available in different configurations, including chilled water on demand.
The refrigerant used is R407C.
• Emerson Network Power Adaptive Power and Cooling: contact details and other news
• Email this article to a colleague
• Register for the free Electronicstalk email newsletter
• Electronicstalk Home Page